Articles

NOVEL OPTIMIZED OPERATION OF WIND SYSTEM BASED SHUNT ACTIVE FILTER (W-SAF) TO MITIGATE THE CURRENT HARMONICS FOR ENERGY CONSERVATION

Volume 14 · Issue 2 Publish Date: March 25, 2015
Full Text PDF
G. VIJAYAKUMAR
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
C. KARTHIKEYAN
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
V. RAVI
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
VIJAYAKUMAR, G., KARTHIKEYAN, C., & RAVI, V. (2015). NOVEL OPTIMIZED OPERATION OF WIND SYSTEM BASED SHUNT ACTIVE FILTER (W-SAF) TO MITIGATE THE CURRENT HARMONICS FOR ENERGY CONSERVATION. ELECTRICA, 14(2), 1825–1835. Retrieved from https://www.electricajournal.org/index.php/pub/article/view/591
Full Text Full Text PDF

Abstract

The paper presents the concept of wind power generation system inverter as SAF under balanced and un-balanced conditions. PV based systems are practically inactive during the night time, Because of the system cannot conserve the energy on the night time. During the night time, the PV-SAF provides only the compensation for the reactive power disturbance through the battery bank. The reference currents extract by the Fuzzy logic controller based instantaneous active and reactive power (p-q) strategy. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy with PI controller is unable to yield an adequate solution when source voltages are not ideal. Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller.

Article Info
Published In
Journal ELECTRICA
Volume / Issue Volume 14 · Issue 2
Pages 1825-1835
History
Published Online March 25, 2015
Copyright
Affiliations
G. VIJAYAKUMAR
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
C. KARTHIKEYAN
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
V. RAVI
Assistant Professor, K.S.R. College of Engineering, Thiruchengode – 637 215, India
Cite this Article
VIJAYAKUMAR, G., KARTHIKEYAN, C., & RAVI, V. (2015). NOVEL OPTIMIZED OPERATION OF WIND SYSTEM BASED SHUNT ACTIVE FILTER (W-SAF) TO MITIGATE THE CURRENT HARMONICS FOR ENERGY CONSERVATION. ELECTRICA, 14(2), 1825–1835. Retrieved from https://www.electricajournal.org/index.php/pub/article/view/591
Outlines